Welcome to the Tork timer instruction manual. This guide provides essential safety warnings, an overview of the timer’s purpose, and basic operating instructions. It explains how the device controls lighting and appliances, and outlines the manual’s structure for easy reference.
The manual is organized into sections for troubleshooting and settings now
Purpose and Scope of the Tork Timer Instruction Manual
This manual is intended to provide all necessary information for the safe and effective use of the Tork SS720 7‑day programmable timer. It explains the purpose of the device, which is to automate the operation of lighting and electrical loads, thereby improving energy efficiency and convenience. The scope of the manual covers the entire lifecycle of the timer: from initial inspection and installation, through routine programming and operation, to troubleshooting and maintenance. This manual also covers installation, programming, and troubleshooting steps to ensure safe and efficient operation. It provides wiring diagrams and safety guidelines for installation!!!?
such as seven programmable on/off cycles per day, a 1‑minute minimum interval, daylight‑savings time adjustment, random mode, manual override, and a rechargeable backup battery. The manual describes how these functions work together to provide flexible control over household appliances and lighting systems.
Safety is emphasized throughout, with warnings about proper handling of electrical connections, the necessity of a neutral wire for single‑pole operation, and the importance of verifying correct wiring before energizing the device. The manual also advises on the correct use of the timer’s on/off button and the procedure for resetting the device in case of power loss.
Warranty details, coverage limits, duration, and the process for claiming service. The manual also outlines the steps for reporting defects or requesting assistance. By following the instructions in this manual, users can achieve reliable performance, extend the lifespan of the timer, and maintain safety and compliance in their electrical installations.

Model Selection and Features
The Tork SS720 offers 7‑day scheduling, 7 on/off cycles per day, 1‑minute minimum, daylight savings, random mode, manual override, and a rechargeable backup battery. It is single‑pole, 120 V, requires neutral, and replaces a standard switch. Ideal for home and commercial use. Now.!
SS720 7-Day Programmable Timer Specification
Model SS720 is a 7‑day programmable timer designed for residential and light commercial use. It supports up to 7 on/off cycles per day, totaling 49 cycles per week, with a minimum interval of 1 minute. The timer operates on 120 V single‑pole circuits and requires a neutral connection. It features a 15‑amp tungsten lamp for status indication, a manual override switch, and a rechargeable backup battery that maintains programming during power outages. The device includes daylight‑savings time adjustment, a random mode option, and a 1‑minute minimum delay for each program. The housing measures 2.5 in × 2.5 in × 1.5 in, weighs 0.8 lb, and is rated for indoor use only. Wiring instructions: connect the black and red wires to the timer’s black and red terminals, the white wire to the white terminal, and the green or bare ground to the green terminal. The timer’s internal firmware supports 7‑day scheduling, daylight‑savings adjustment, and random mode, all configurable via the rotary dial and push‑button interface; The rechargeable battery is a 3.6 V, 200 mAh Li‑ion cell, providing up to 24 hours of backup power. The unit’s power consumption is 0.5 W when idle and 2 W during operation. Warranty: 2‑year limited warranty covers manufacturing defects. For support, contact the manufacturer at 888‑500‑4598 ext. 436.
The enclosure is ABS plastic, rated IP20 for indoor use, with a clear front panel and a 0.5‑inch status LED. The 3.6 V Li‑ion battery (200 mAh) supplies up to 24 hours of standby power. Dimensions: 2.5 in × 2.5 in × 1.5 in; weight 0.8 lb. UL 1449!.

Wiring and Installation
Connect the timer’s black wire to the line, red to load, white to neutral, and green to ground. Use a 120 V single‑pole circuit. Verify polarity by testing with a lamp. Secure the timer in a dry box, then turn power back on to confirm operation. Ensure proper grounding. Follow local codes for safety. and test;!!.
Single-Pole Wiring Procedure
Before starting, turn off the circuit breaker to ensure safety. Remove the existing single‑pole switch and note the two wires that feed the switch. These wires are the line (black or red) and the load (black or red). The neutral wire (white) and ground (green or bare) must also be present. If the box lacks a neutral, the timer cannot be wired and should be replaced with a model that does not require one.
Connect the timer’s black wire to the line wire, and the red wire to the load wire. The white wire on the timer should be tied to the neutral bundle in the box, using a wire nut. The green or bare ground wire on the timer must be attached to the box’s grounding screw or the bare ground bundle. If the box has no ground, the timer’s green wire should be connected to the metal box itself.
Use a 120 V single‑pole circuit. Verify that the timer’s power rating matches the load’s amperage. After wiring, secure the timer in the electrical box, replace the cover plate, and restore power. Test by pressing the ON‑OFF button; the connected device should turn on. If it does not, reverse the black and red connections.
Always double‑check that the neutral is correctly connected, as a missing neutral will cause the timer to fail to power the load. Follow local electrical codes and the manufacturer’s safety instructions. If you are uncertain, consult a licensed electrician.
Ensure timer’s fuse is intact; a blown fuse will stop operation. If a fault light appears, replace fuse and reset before use.

Advanced Programming Options
Enable daylight savings by pressing the DS button, then set the offset. Random mode activates by selecting R and choosing a range. These features allow flexible scheduling for seasonal changes and unpredictable operation. Use the timer’s menu to fine‑tune settings and logs!

Daylight Savings Time Adjustment and Random Mode
To adjust for daylight savings, press the DS button until the indicator lights. Then set the desired offset by rotating the dial clockwise for a forward shift or counter‑clockwise for a backward shift. Confirm by pressing OK. The timer will automatically apply the offset each year, ensuring accurate operation without manual reprogramming.
Random mode introduces variability into the schedule. Activate by pressing the R button, then choose the random range using the dial. The timer will generate a new ON/OFF time within the selected range each cycle, ideal for applications requiring unpredictable operation such as security lighting or irrigation systems. To disable random mode, press R again until the indicator turns off.
Both features coexist seamlessly. When daylight savings is active, random mode still respects the offset, maintaining correct timing. Users can combine these options with the standard 7‑day program to create sophisticated, adaptive schedules. For detailed troubleshooting, refer to the troubleshooting section.
When using random mode, the timer’s internal clock continues to track the real time, ensuring that the random offsets are applied relative to the scheduled periods. If you need to reset the random seed, press the R button three times quickly; the indicator will flash, confirming a new seed. This feature is useful when you want to avoid predictable patterns over long periods.
Press Save after changes; otherwise settings revert on power loss.now

Power Requirements and Backup
The Tork SS720 operates on a standard 120‑V AC supply, single‑pole. A built‑in rechargeable backup battery ensures continuity during outages. The battery is charged automatically when mains power returns. Replace the battery every 2‑3 years for optimal performance. Battery life is monitored via the LED display. Now
Voltage Requirements and Rechargeable Backup Battery
The Tork SS720 timer is designed for 120‑V AC single‑phase residential circuits. It draws a maximum of 15 A, with a continuous current rating of 1 A for the internal electronics. Input terminals are marked L (line) and N (neutral); the neutral must be connected to a grounded neutral bus. The internal transformer steps down the line voltage to 12 V DC for the control board and 3.7 V for the lithium‑ion backup cell. The backup battery is a sealed 3.7 V Li‑Ion cell with a nominal capacity of 1.5 Ah, capable of sustaining the timer’s 1 A load for up to 24 hours of power loss. The battery is charged through a dedicated charging circuit that monitors voltage and temperature; it automatically disconnects when the battery reaches full charge, preventing over‑charging. A small LED indicator on the front panel flashes amber during charging and turns green when the battery is fully charged. The battery should be inspected annually for physical damage or swelling; if any abnormality is observed, replace the cell immediately. Replacement batteries are available from the manufacturer’s support portal and must be installed in the same orientation (positive to positive, negative to negative). The timer’s firmware will alert the user via the display if the battery voltage drops below 3.4 V, prompting a replacement. In addition, the device includes a low‑power mode that reduces the display brightness and disables non‑essential functions when battery voltage is low, extending backup time. For safety, do not attempt to open the battery compartment; the internal components are sealed and may contain hazardous materials. It meets UL and IEC safety.!! The timer meets UL and IEC safety standards. It is rated for continuous use.

Troubleshooting Common Issues
Check wiring, ensure correct polarity, and verify neutral connection. If lights fail, reverse line and load leads. For no display, test power supply and replace the backup battery. Reset by holding the ON/OFF button for 10 s. Contact support if problems persist.—Check manual.
Incorrect Wiring Detection and Fixes
When the timer fails to power or the load does not activate, wiring is usually the culprit. The SS720 requires a neutral, a line (black), and a load (red). Follow these steps to locate and correct errors.
- Verify Power. With the breaker on, use a multimeter to confirm 120 V between black and white. If no voltage, check the upstream breaker and cable.
- Check Line/Load. The black wire is line; the red is load. If the load fails, reverse black and red. A quick swap test confirms polarity.
- Confirm Neutral. Connect the timer’s white to the building neutral bus or, if absent, to the bare ground and green grounds together, then use green as neutral.
- Grounding. Tie the green (or green‑with‑yellow) wire to the metal box or grounding screw. Missing ground triggers protection.
- On/Off Test. Press the ON/OFF button. If the indicator lights and the load turns on, wiring is correct; if not, double‑check line/load swap and neutral.
- Reset. After corrections, hold ON/OFF for 10 s to reset the unit and clear fault codes.
- Diagram. Refer to the schematic for your model (SS720, SS700Z, SS721Z) to verify terminal assignments.
- Support. If problems persist, contact Tork support at 888‑500‑4598 ext. 436.


These steps resolve most wiring issues and restore proper operation. Disconnect power before making any changes.
Always verify connections with a voltage tester before finalizing!!

Manufacturer Support and Warranty
For assistance, call Tork Support at 888‑500‑4598 ext. 436. Warranty covers manufacturing defects for 2 years from purchase. Return the unit in original packaging. Email support@tork.com for claims. Follow the return form on the website. No coverage for user damage. Warranty ends after 2 years. Contact support!!
Contact Information and Warranty Terms
For all inquiries regarding the Tork SS720 7‑Day Programmable Timer, please contact support team. Phone: 888‑500‑4598 ext. 436. Email: support@tork.com. chat is available Monday through Friday, 8 a.m. to 6 p.m. Eastern Standard Time. For international customers, call +1‑800‑TORK‑HELP (844‑764‑4357) and select appropriate country code. Our website hosts a FAQ, downloadable user guides, a warranty claim portal at www.tork.com/warranty. The standard warranty covers manufacturing defects for a period of two (2) years from the date of purchase. This warranty does not cover damage resulting from misuse, accidental damage, or unauthorized modifications. To file a claim, complete the online form, attach a copy of the original receipt, and return the product in its original packaging. Shipping costs for return items are the responsibility of the customer unless the defect is proven to be a manufacturing fault. Warranty claims are processed within 10 business days of receipt. All warranty coverage is subject to the terms and conditions outlined in the Tork Warranty Statement, which can be found on the website or in the printed manual. The warranty is void if the product is used with a voltage or current rating outside the specified limits, if the timer is installed in a location with excessive moisture or temperature beyond the recommended operating range, or if the timer is subjected to electrical surges not protected by a surge‑suppressing device. The warranty does not cover the cost of labor for installation or removal of the timer. We appreciate your trust in Tork products and are committed to ensuring your satisfaction with our timers. Thank you for choosing Tork